Model nomenclature, Versatec ultra series installation manual – WaterFurnace Versatec Ultra User Manual
Page 4

4
VERSATEC ULTRA SERIES INSTALLATION MANUAL
Model Nomenclature
U
S
1
3
4-6
7
8
9
Model Type
U – Versatec Ultra
Operation Range
S – Single Stage
Cabinet Configuration
V – Vertical
H - Horizontal
Unit Capacity (MBTUH)
009, 012, 015, 018,
023 (Horizontal)
024, 030, 036,
041 (Vertical)
042, 048, 060, 070
Discharge Configuration
T – Top (Vertical)
E – End (Horizontal)
S – Side (Horizontal)
Return Air Configuration
L – Left
R – Right
Voltage
0 – 208-230/60/1
2 – 265-277/60/1 (009-036)
3 – 208-230/60/3 (023-070)
4 – 460/60/3 (023-070)
5 – 575/60/3 (PSC Only 041-070)
Hot Water Generation Option
2
0 – No HWG, No IntelliStart
®
2 – HWG w/o Pump, No IntelliStart
(Vertical 015-070)
3 – No HWG, IntelliStart
5 – HWG w/o Pump, IntelliStart
(Vertical 018-070)
Blower Options
0 – PSC Blower
1 – Variable Speed ECM Blower (015-070)
2 – High Static Variable Speed ECM Blower
(042-048)
3 – High Static PSC Blower (024, 030, 042, 048)
4 – 5-Speed ECM Blower (015-070)
Water Coil Option
C – Copper
N – CuproNickel
Vintage
* - Factory Use Only
Non-Standard Options
SS – Standard
Drain Pan Option
0 – Composite, No Secondary Connection
1 – Composite, Secondary Connection
2 – Stainless Steel, No Secondary Connection
3 – Stainless Steel, Secondary Connection
Cabinet Option
0 – Unpainted, 1 in MERV 4, Filter Rail
1 – Painted, 1 in MERV 4, Filter Rail
2 – Unpainted, 2 in MERV 13, Filter Rail
3 – Painted, 2 in MERV 13, Filter Rail
4 – Unpainted, 1 in MERV 4, Filter Rack
5 – Painted, 1 in MERV 4, Filter Rack
6 – Unpainted, 2 in MERV 13, Filter Rack
7 – Painted, 2 in MERV 13, Filter Rack
Phase Guard
1
N – No Phase Guard, No Disconnect
P – Phase Guard, No Disconnect
B – Phase Guard, Disconnect
D – No Phase Guard, Disconnect
All-Aluminum Air Coil Option
5 – AlumiSeal
TM
/Extended Range
6 – AlumiSeal/Standard Range
7 – No Coating/Extended Range
8 – No Coating/Standard Range
Control Option
A – Aurora
TM
Base Control (ABC)
E – Aurora UPC DDC Controller
F – Aurora UPC DDC Controller with LON
Water Control Option
N – None
R – Water Flow Regulator (015-070)
V – 2-Way Valve (015-070)
B – 2-Way Valve w/ Water Flow Regulator
(015-070)
Refrigeration Option
0 – None
G – Hot Gas Bypass (015-072)
R – Hot Gas Reheat (015-072)
B – Hot Gas Bypass w/Hot Gas Reheat (015-072)
Sound Kit Option
A – None
B – Sound Kit (Not Available on H009-012)
Rev.: 24 April 2014D
10
11
12
14
V
036
T
L
0
0
0
C
A
N
13
N
15
A
16
5
17
N
18
0
19
0
20
SS
21-22
*
23
Notes:
1 - Phase Guard Only Available on 208-230/60/3, 460/60/3, and 575/60/3
2 - IntelliStart is not available with Phase Guard
2