Wiring schematics, Versatec ultra series installation manual, Legend – WaterFurnace Versatec Ultra User Manual

Page 28: Aurora base control (abc)

background image

28

VERSATEC ULTRA SERIES INSTALLATION MANUAL

Wiring Schematics

Aurora Base Control 208-230/60/1 PSC with IntelliStart

P13

P4

SW1

P5

JW2

P9

ES
LS

LO

O/B

Y2
W
DH

P2

P8

P7

RS485 NET

RS485 NET

P6

RS485 EXP

P3

SW2

On

Reheat/Normal

L – Pulse/Continuous

CC – Dual/Single

Acc – Dip 2

Acc – Dip 1

RV – B/O

FP2 – 15°F/30°F

FP1 – 15°F/30°F

F1

P1

C

PWM

1

2

3

4

5

6

7

8

ALM
ALG
ACC COM
ACC NO
ACC NC

R
C

G

Y1

EH2

C

EH1

C

CO

C

R A- B+

C

R A- B+

Off

Fault

R

Status

G

Config

Y

DH W Y2 Y1 G O/B C

R LO

R

F FG CC CCG

CC2

HI

CC2

LO

CC2

G

REV REV FP1 FP1 FP2 FP2 LPS LPS HPS HPS

Aurora Base Control

(ABC)

K1

K2

K3

K4

K5

K6

N/A

CFM

F

R

C

CC

G

Y1

C

R

Transformer

Thermistor

Relay Coil

Switch - Condensate Overflow

Switch - High pressure

Switch - Low pressure

Polarized connector

Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Voltage Wiring
Field Line Voltage Wiring
Optional Block
DC Voltage PCB Traces

Internal Junction
Quick Connect Terminal

Field Wiring Lug

Ground

Relay Contacts – N.O., N.C.

Field Zone Sensor Wiring

Legend

L1

Capacitor

T

1

2

3

CC – Compressor Contactor
CO – Condensate Overflow Sensor
ES – Emergency Shutdown
HP – High Pressure Switch
LP – Low Pressure Switch
FD – Freeze Detection Sensor
F1 – Fuse

1 – Optional, factory installed unit mounted disconnect.
2 – Swap blue and red leads for 208V operation.
3 – Optional, factory installed internal isolation valve.

Notes:

Condensate

Brown (23)

Black/White

Green

Yellow

Black/White

Yellow

Slow Flash
Fast Flash
Flash Code

Status LED (LED1, Green)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)

Status LED (LED1, Green)

Normal Mode
Control is Non-Functional
Test Mode
Lockout Active
Dehumidification Mode
Reserved
Reserved
Load Shed
ESD

1 second on and 1 second off

Random Start Delay

Fast Flash

OFF

ON

Slow Flash

Fast Flash

Flash Code 2
Flash Code 3

Flash Code 6

Flash Code 4
Flash Code 5

Aurora LED Flash Codes

100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating

Reserved

Flash Code 7

Configuration LED (LED2, Yellow)

Fault LED (LED3, Red)

Fast Flash
Fast Flash

No Software Overide

Flash ECM Setting

DIP Switch Overide

Slow Flash

Normal Mode
Input Fault Lockout
High Pressure Lockout
Low Pressure Lockout

Low Water Coil Limit Lockout - FP1

Low Air Coil Limit Lockout - FP2

Reserved
Condensate Overflow Lockout
Over/Under Voltage Shutdown
Reserved
Reserved
Air/Water Coil Limit Sensor Error

Flash Code 1

OFF

Flash Code 2
Flash Code 3
Flash Code 4
Flash Code 5

Flash Code 8

Flash Code 6
Flash Code 7

Flash Code 9

Flash Code 10
Flash Code 11

ECM Configure Mode

Fast Flash

Reset Configure Mode

Off

Fuse

SW1 – Push button
SW2 – DIP package 8 position
RB – Blower Relay
RV – Reversing Valve Coil

2

1

3

Isolation

Valve

Red
(51)

Green

(50)

White

(52)

Note 3

Note 3

Red

(53

)

Light Emitting Diode - Green

G

Light Emitting Diode - Yellow

Y

Light Emitting Diode - Red

R

97P817-02 11/08/10

L1

L2

CC

T1

T2

H

M

L

P3

PSC

Blower

Motor

Grn

Wht

Brn

Cap

3 Airflow
Settings

Black

White

Black

Blue

230V

Black

Red

208V

Note 2

1

3

RB

Note 1

Black (95)

Red (97)

Disconnect

Neutral

Ground

L1

L1

L2

L2

L3

L3

Unit Power Supply

208-230/60/1

G

Green (93)

Compressor

Cap

C

R

S

Black

Tan

Red

Blue

Soft Start

Run Winding

Active

Start Winding

Common Winding

Red

Pink

Pink

Blue

Black

Black

Blue

Accessory Relay

Cycle with Blower

Cycle with Compressor

Water Valve Slow Open

Outdoor Air Damper

SW2-4 SW2-5

On

On

Off

Off

On

Off

Off

On

Operation

Event

Normal Mode

Test Mode

Random Start Delay
Compressor On Delay
Compressor Minimum On Time
Compressor Short Cycle Delay
Blower Off Delay
Fault Recognition Delay – High Pressure
Start-Up Bypass – Low Pressure
Fault Recognition Delay – Low Pressure
Start-Up Bypass – Low Water/Air Coil Limit
Fault Recognition Delay – Low Water/Air Coil Limit
Fault Recognition Delay – Condensate Overflow
Thermostat Call Recognition Time
Auxiliary Heat Staging Delay
Emergency Heat Staging Delay

Less than 1 second

5 to 80 seconds

1 second

5 seconds

< 1 second

30 seconds

2 seconds

Less than 1 second

2 minutes

5 seconds

4 minutes

15 seconds

2 minutes

2 minutes

30 seconds

30 seconds

30 seconds

30 seconds
30 seconds

30 seconds
30 seconds
30 seconds

2 seconds

2 seconds

5 minutes
2 minutes

20 seconds

7.5 seconds

Aurora Timing Events

Reheat Delay

30 seconds

30 seconds

Water Valve Slow Open Delay

90 seconds

90 seconds

24V

RB

CC

Ÿ

Ÿ

Resistor

White

(12

)

Black

(13

)

Violet
(14

)

Black (15)

Oran

ge

(01

)

Oran

ge

(02

)

RV

HP

LP

T

FD

RV

Blue

(07

)

Blue

(08

)

Black (09)

Black (10)

Yellow

Yellow

LED4

LED5

G