beautypg.com

Hot water generator connections, Water tank preparation, Plumbing installation – WaterFurnace Versatec Ultra User Manual

Page 16

background image

16

VERSATEC ULTRA SERIES INSTALLATION MANUAL

Hot Water Generator Connections

The heat reclaiming hot water generator coil is of vented

double-wall copper construction and is suitable for

potable water.

To maximize the benefits of the hot water generator a

minimum 50-gallon water heater is recommended. For

higher demand applications, use an 80-gallon water heater

or two 50-gallon water heaters connected in a series as

shown below. Electric water heaters are recommended.

Make sure all local electrical and plumbing codes are met

for installing a hot water generator. A water softener is

recommended with hard water (greater than 10 grains or

170 total hardness).

Typical Hot Water Generator Installation

Drain Valve

In

P/T Relief

Valve

Cold

Water In

Hot

Water Out

HWG

Water In

HWG

Water Out

Ball Valve

3/4 in. x 3/4 in. x 1/2 in. Tee

Vent

Field Installed

HWG Pump

CAUTION: Elements will burn out if energized dry.

Hot Water Generator Installation In Preheat Tank

In

Ball Valve

3/4 in. x 3/4 in. x 1/2 in. Tee

Cold

Water In

Hot

Water Out

P/T Relief

Valve

P/T Relief

Valve

HWG

Water In

HWG

Water Out

Drain Valve

Vent

Field Installed

HWG Pump

NOTE: This configuration maximizes hot water

generator capability.

Water Tank Preparation

To install a unit with a hot water generator, follow these

installation guidelines.

1. Turn off the power to the water heater.

2. Attach a water hose to the water tank drain connection and

run the other end of the hose to an open drain or outdoors.

3. Close the cold water inlet valve to the water heater tank.

4. Drain the tank by opening the valve on the bottom of the

tank, then open the pressure relief valve or hot water faucet.

5. Flush the tank by opening the cold water inlet valve to

the water heater to free the tank of sediments. Close

when draining water is clear.

6. Disconnect the garden hose and remove the drain valve

from the water heater.

7. Refer to Plumbing Installation and Hot Water

Generator Startup.

Plumbing Installation

1. Inspect the dip tube in the water heater cold inlet

for a check valve. If a check valve is present it must

be removed or damage to the hot water generator

circulator will occur.

2. Remove drain valve and fitting.

3. Thread the 3/4-inch NPT x 3-1/2-inch brass nipple into

the water heater drain port.

4. Attach the center port of the 3/4-inch FPT tee to the

opposite end of the brass nipple.

5. Attach the 1/2-inch copper to 3/4-inch NPT adaptor to

the side of the tee closest to the unit.

6. Install the drain valve on the tee opposite the adaptor.

7. Run interconnecting tubing from the tee to HWG

water out.

8. Cut the cold water “IN” line going to the water heater.

9. Insert the reducing solder tee in line with cold water

“IN” line as shown.

10. Run interconnecting copper tubing between the unit

DHW water “IN” and the tee (1/2-inch nominal). The

recommended maximum distance is 50 feet.

11. To prevent air entrapment in the system, install a vent

coupling at the highest point of the interconnecting lines.

12. Insulate all exposed surfaces of both connecting water

lines with 3/8-inch wall closed cell insulation.

NOTE: All plumbing and piping connections must comply

with local plumbing codes.