Axess elite user manual – SurgeX SX-AX20E User Manual
Page 29
![background image](/manuals/742470/29/background.png)
Axess Elite
User Manual
Firmware Version v1.06.227
© SurgeX | Technical Support: 800-645-9721 | surgex.com
Descriptors
Inform
Description
Payload
eInform_outletStatus
This inform is used to tell the manager the status of
all 8 outlets. It is also the response to the
getOutletStatus and setOutletStatus commands.
tOutletStatus
eInform_auxRelayStatus
This inform is used to tell the manager the status of
the 2 auxiliary relays. It is also the response to the
getAuxRelayStatus and setAuxRelayStatus commands.
tAuxStatus
eInform_lineVoltage
This inform is used to tell the manager the line
voltage. It is also the response to the getLineVoltage
command.
tLineVoltage
eInform_lineCurrent
This inform is used to tell the manager the total line
current. It is also the response to the getLineCurrent
command.
tLineCurrent
eInform_linePower
This inform is used to tell the manager the total line
power. It is also the response to the getLinePower
command.
tLinePower
eInform_outletCurrent
This inform is used to tell the manager the current
draw of each of the individual outlets. It is also the
response to the getOutletCurrent command.
tOutletCurrent
eInform_outletPower
This inform is used to tell the manager the power
draw of each of the individual outlets. It is also the
response to the getOutletPower command.
tOutletPower
eInform_sysStatus
This inform is used to tell the manager the entire
system status (all above metrics). It is sent every X minutes
by the managed device to keep the manager in sync. It is
also the response to the getSysStatus command.
tSysStatus
eInform_poll
This inform is used as the response to the Poll
command. The Poll command is used by the Axess
Elite to poll Expansion units.
tPoll
eInform_overVoltage
This inform is sent whenever a
System Trigger: Over Voltage occurs.
tInformOverVoltage
eInform_underVoltage
This inform is sent whenever a
System Trigger: Under Voltage occurs.
tInformUnderVoltage
eInform_overCurrent
This inform is sent whenever a
System Trigger: Over Current occurs.
tInformOverCurrent
eInform_overTemperature
This inform is sent whenever a
System Trigger: Over Temperature occurs.
tInformOverTemperature
eInform_selfTestFail
This inform is sent whenever a
System Trigger: Self Test Failure occurs.
None
eInform_userTriggerClear
This inform is sent whenever any User Trigger clears.
tInformUserTriggerClear
eInform_userTriggerFail
This inform is sent whenever any User Trigger fails.
tInformUserTriggerFail
eInform_manualControl
eInform_systemTriggerClear
This inform is sent whenever a manual outlet state
change is made.
This inform is sent whenever any System Trigger
clears.
tInformManualControl
tInformSystemTriggerClear