6.5
Device Commands
Command
Description
Admi
Fact Def
get all
get outlets get status
Returns the status of all AC outlets and the following system level measurements:
•
Device Name
•
Line Voltage
•
Total Current Draw
•
Total Power Draw
•
Total Energy Used
•
Reboot Time currently in use
•
Delay Time currently in use
•
Temperature
•
On/Off status of each outlet
•
Current draw of each outlet
•
Power Draw of each outlet
No
get outlet <1
‐10>
Returns the status of the specified outlet. AC outlets are numbers 1-8. Aux Relays
A and B are numbers 9 and 10.
No
set outlet <1
‐10>
Sets the selected outlet to the selected state. The user must have rights to
the selected
No
get devicename
Returns the device name.
No Axess ELITE
set devicename
Sets the device name.
Yes
get reboot
Returns the Reboot Time.
No
set reboot <1-99>
Sets the Reboot Time in seconds.
No
5
get delay
Returns the Delay Time.
No
set delay <0-99>
Sets the Delay Time in seconds.
No
1
get console
Returns the current console timeout and baud rate.
No
set autologout <0-99>
Sets the automatic logout timeout of web and CLI in minutes. 0 = no timeout.
Yes
2
set baud < 2400 | 9600 | 57600 | 115200 > Sets the serial port baud rate.
Yes
9600
clear shutdown
Clears a persistent shutdown state.
No
set clear shutdown by user < yes | no >
Sets the ability of a user account to clear a persistent shutdown state.
Yes
Y
get upload enable
Returns the status of the ability to accept a firmware upload.
No
set upload enable < yes | no >
Sets the ability to accept a firmware upload.
Yes
Y
clear log
Clears history text log file.
Yes
set factory defaults
Resets all parameters, except Network Settings, to their factory default settings.
Confirmation is required. Note: This command may take up to 30 seconds to execute.
Yes
logout
Ends the session.
No
reboot
Reboots the unit. Will not affect the status of the outlets.
No