I. introduction – SurgeX CM-1115-RT-AR User Manual
Page 4

CM-1115(20)-RT-AR User Manual
Page 3
I.
Introduction
The SurgeX
®
CM-1115(20)-RT-AR is a network attached, IP addressed, web controlled AC surge
eliminator and power conditioner. The CM-1115(20)-RT-AR may be used to switch up to 15A/20A
at 120V. The simple web server structure allows basic control of two outlets. The extensive
programming and setup capabilities are accessed by a web browser, through a Device
Management Utility (DMU), or through a Command Line Interface (CLI).
The CM-1115(20)-RT-AR features SurgeX
®
Advanced Series Mode
®
surge elimination,
Impedance Tolerant EMI/RFI filtering, SurgeX ICE
®
Inrush Current Elimination, SurgeX
®
CouVs
®
Catastrophic Over/Under-Voltage Shutdown, and low level control inputs/outputs.
• Remote reboot any device: monitors, routers, servers, kiosks, etc. The remote device need
not be network attached.
• Conserve energy by powering down equipment when not in use.
• Telnet access uses the Command Line Interface (CLI) structure and syntax to completely
configure and control the CM-1115(20)-RT-AR. This Axess Ready (AR) device also
supports the DxP protocol, which allows software developers to integrate the unit into
custom applications.
• Up to 2 systems can be continuously monitored with AutoPing, with automatic power
control upon loss of contact. Reboot crashed systems, or provide auto power-up or -down
for environmental controls and notification systems.
• The CM-1115(20)-RT-AR utilizes 2 levels of password security, with only the
administrative account having access to setup and configuration.
• Accepts both DC voltage and contact closure control inputs.
• Two or more units can be cascaded together for larger systems.
• Auxiliary relay output can be used to control other SurgeX
®
products.
• 12 Volt DC output can be used to control other SurgeX
®
products or drive LEDs.
• Auxiliary relay or 12 Volt DC output can be used to provide confirmation feedback.