User’s Manual Pub. 0300241-01 Rev. A

Chapter 4

Module Data, Status, and
Channel Configuration

After installing the 1769sc-IR6I Isolated RTD/Resistance Input Module, you must
configure it for operation, usually using the programming software compatible with the
controller (for example, RSLogix 500 or RSLogix 5000). Once configuration is complete
and reflected in the ladder logic, you need to operate the module and verify its
configuration.

This chapter contains information on the following:

Module memory map

Configuring channels

Accessing input image file data

Section 4.1

Module
Memory Map

The module uses eight input words for data and status bits (input image), and seven
configuration
words.

Note: Not all controllers support program access to the configuration file. Refer to
your controller’s user manual.




Input Image

File

Input Image

8 words

Configuration

File

12 Words

Channel 0 Data Word

Channel 1 Data Word

Channel 2 Data Word

Channel 3 Data Word

Channel 4 Data Word

Channel 5 Data Word

General/Open-circuit Status

Bits

Over/Under Range Status Bits

Channel 0 Configuration Word

Channel 1 Configuration Word

Channel 2 Configuration Word

Channel 3 Configuration Word

Channel 4 Configuration Word

Channel 5 Configuration Word

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Not Used

Memory Map

Word 0

Word 1

Word 2

Word 3

Word 4

Word 5

Word 6

Word 7

Word 0

Word 1

Word 2

Word 3

Word 4

Word 5

Word 6

Word 7

Word 8

Word 9

Word 10

Word 11

Word 12

Slot e




Configuration

File

Slot e