Table 10. Wind/Snow Load Chart: Flat, 2 Sides Clamped, Single Panel, Single Span.

Max Recommended Span, on Center, between Width Supports, under Progressive Wind/Snow Loads:

Max. Support Distance (Glazing Width) (mm / in.)

PALSUN Type (mm)

Uniform Load

4

5

6

8

10

12

kg/m2

psf

mm in. mm in. mm in. mm in. mm in. mm in.

50 10

780

31

980

39

1280

51

1800

71

1950

78

2050

81

80 16

680

27

820 33

1150

46

1680

66

1850

73

2050

81

100 20 620

25

700

28

1080

43

1550

61

1780

70

2020

80

120 25 580

23

620

25

980

39

1400

55

1700

67

1950

77

150 30 420

17

580

23

850

34

1180

47

1600

63

1780

70

200 40 NA

NA 420

17

650

26

1050

42

1480

59

1550

61

250 50 NA

NA

NA

NA 450

18

950

38

1280

51

1350

53

300 60 NA

NA

NA

NA

NA

NA 820

33

1080

43

1220

48

Note:
Preceding General Glazing Comments & Table 9. notes above pertain also for this table.


Figure 9. Typical

Flat PALSUN Glazing, Skylight Canopy over Main Entrance.

ORT Technical College, Natanya, Israel.
Cold-Bent, Angled Frameless Ridge, 6mm Clear PALSUN.
PALGARD may be Used, but Bending at the Ridge will Damage Silica Coat along Bent Line.