Glazing guide – Palram PALGAR User Manual
Page 18
![background image](/manuals/740082/18/background.png)
PALSUN® PALGARD™
Glazing Guide
18
Table 9. Wind/Snow Load Chart. Flat, 4 Sides Clamped, Single Panel, Single Span.
Max Recommended Span, on Center, amid Width Supports (Shorter glazing dimension),
under Progressive (light to heavy) Wind/Snow Loads, at Various Glazing Ratios:
Max. Support Span (Glazing Width) according to Ratio
a:b
Thickness
(Gauge)
Wind/Snow
Uniform Loads
Ratio 1:1 to 1:1.2
Ratio 1:1.2 to 1:1.5 Ratio 1:1.5 to 1:1.8
mm
in.
kg/m2
psf
mm
in.
mm
in.
mm
in.
50 10 1200 48 1150 46 1050 42
80 15 1150 46 1050 42 1000 40
120 25 1080 43 1020 41 920 37
150 30 1020 41 980 39 880 35
4
5
/
32
200 40 980 39 880 35 800 32
50 10 1350 54 1280 51 1200 48
80 15 1280 51 1180 47 1100 44
120 25 1180 47 1100 44 1020 41
150 30 1120 45 1020 41 950 38
200 40 1020 41 950 38 880 35
5
13
/
32
250 50 950 38 880 35 800 32
50 10 1650 66 1580 63 1520 61
100 20 1480 59 1420 57 1350 54
150 30 1320 53 1250 50 1180 47
200 40 1200 48 1120 45 1020 41
250 50 1080 43 980 39 880 35
6
¼
300 60 920 37 850 34 750 30
50 10 2050 81 1920 77 1780 71
80 15 1820 73 1750 70 1620 65
120 25 1750 70 1620 65 1480 59
150 30 1620 65 1480 59 1320 53
200 40 1480 59 1350 54 1180 47
250 50 1350 54 1200 40 1050 42
8
5
/
16
300 60 1220 41 1080 43 920 37
50 10 2050 81 2050 81 1950 78
100 20 2050 81 1920 77 1780 71
150 30 1900 76 1750 70 1650 66
200 40 1750 70 1580 63 1480 59
250 50 1580 63 1400 56 1320 53
10
13
/
16
300 60 1400 56 1220 41 1080 43
50 10 2050 81 2050 2050 81
100 20 2050 81 2050 81 2050 76
150 30 2050 81 1920 75 1880 69
200 40 1880 75 1720 69 1550 52
250 50 1720 69 1580 63 1400 56
12
½
300 60 1550 62 1420 57 1220 49
Notes:
1. For a glazing ratio smaller than 1:1.8 see “Table 10. Flat, 2 Sides Clamped PALSUN Load Chart”.
2. Glazing table begins with 4mm (5/32”)thickness as the lowest thickness recommended for permanent quality glazing.
Thinner sheets fit signs, advertising, vacuum-forming, agricultural structures, temporary pavilions etc.