Ntellisys, Daptive, Ressure – Nor-Cal IQ+ Adaptive Pressure Controller User Manual
Page 23: Ontrollers, 3 - devicenet object, 1 - identity object, 2 - message router object, 4 - assembly object

Call toll free
800-84-4166
or 530-842-4457
•
FAX 530-842-9130
I
ntellIsys
A
dAptIve
p
ressure
C
ontrollers
IQ+ OP-LIT 9/08
8.3 - DeviceNet Object
Class ID 3
hex
Instance ID 1
•
The values of attribute 1 and 2
are retrieved from NVRAM if
the front panel switches are set to
program mode; otherwise, the
value selected by the front panel
switch is reported.
•
The set service of attribute 1 and 2
directly updates the value for these
attributes in NVRAM. When setting
the MAC ID, the device will auto-
matically reset. To update baud rate,
a manual hardware or software reset
has to be executed.
•
The value of attributes 2 and 9 are
decoded as follows: 0=125Kb, 1=250Kb, 2=500Kb
8.1 - Identity Object
Class ID 1
hex
Instance ID 1
• vendor ID:
Assigned number to
Nor-Cal Products Inc. is 612
• Device type:
The value of 1D
hex
is used for process control valve
(cf. specification One, Edition 3.3,
page 6-182)
•
Product code:
Nor-Cal Products
attributes a specific product code
as a function of the valve size or
type.
8.2 - message Router Object
Class ID 2
hex
Instance ID 1
No class or instance attributes supported.
TAbLE 8.3.1 – DEvICENET ObJECT ATTRIbUTES AND SERvICES
attrIBute Id
HEx
ServIce Id
HEx
name
Format
value
1
0E (get) 10 (set)
MAC ID
USINT
0-63 (from NVRAM in P mode)
2
0E (get) 10 (set)
Baud Rate
USINT
0-2 (from NVRAM in P mode)
5
0E (get)
Allocation info
Byte+Byte
Allocation choice + master ID
6
0E (get)
MAC ID switch
changed
BOOL
0 = No Change,
1 = Change since last reset or
power-up
7
0E (get)
Baud rate switch
changed
BOOL
0 = No Change,
1 = Change since last reset or
power-up
8
0E (get)
MAC ID switch
value
USINT
0-99
9
0E (get)
Baud rate switch
value
USINT
0-9
None
4B
Allocate master/slave connection
None
4C
Release master/slave connection
TAbLE 8.1.1 – IDENTITy ObJECT ATTRIbUTES AND SERvICES
attrIBute Id
HEx
ServIce Id
HEx
name
Format
value
1
0E (get)
Vendor ID
UINT
612 (264 h) (ROM)
2
0E (get)
Device Type
UINT
00 1D (ROM)
3
0E (get)
Product Code
UINT
00 xx (NVRAM)
4
0E (get)
Revision
UINT(maj.)+UINT(min.)
xx xx (ROM)
5
0E (get)
Status
WORD
See table 8.1.2
6
0E (get)
Serial Number
32 bits (6 digits)
xxxxxx (NVRAM)
7
0E (get)
Product Name
String <=32
“INTELLISYS” (ROM)
None
05 (reset)
Invokes reset service: 0 = DeviceNet reset (default reset)
1 = out of box reset (NVRAM reset + DeviceNet reset)
64h = device power cycle
TAbLE 8.1.2 IDENTITy ObJECT STATUS bIT
mAP
BIt
deFInItIon
0
Owned
1
Reserved (=0)
2
Configured
3
Reserved (=0)
4-7
Extended device status
8
Minor recoverable fault
9
Minor unrecoverable fault
10
Major recoverable fault
11
Major unrecoverable fault
12-15
Reserved (=0)
8.4 - Assembly Object
Class ID 4
hex
Instance ID (see static assembly Table 9.5.1 and 9.5.2)
Get or set service selectively supported as a function of
the selected instance in the connection object.
TAbLE 8.4.1 – ASSEmbLy ObJECT ATTRIbUTES
attrIBute Id
hex
ServIce Id
HEx
name
Format
value
3
0E (get) 10 (set)
Data
ARRAY
Static assembly