SPARE PARTS & ACCESSORIES
81
accePtaBle fluidS for Manikin
cleaning fluids
To clean the manikin’s fluid system use one of the following:
• 60% Isopropanol alcohol
• 70% Ethanol
SiMulated iv fluidS
Only use purified water to simulate IV fluids:
• Distilled Water
• Deionized Water
Regulatory Information
federal coMMunicationS
coMMiSSion StateMent
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received,
including interference that may cause undesired operation.
caution
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
Note: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and
receiver.
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician
for help.
Laerdal Medical AS hereby declares that when carrying the
CE-mark, this product is in compliance with the essential
requirements and other relevant provisions of Directive
1999/5/EC.
Dispose of in accordance with local requirements and
regulations.
Li-ion batteries should be recycled
Spare Parts and Accessories
Substitute XX with the number for your local language version
tranSPort & StoraGe caSeS
212-17950
Case soft, torso
212-18050
Case soft, legs
PcS & equiPMent
213-090XX Instructor PC, 12”
213-091XX SimMan Essential, Rugged Instructor PC`s
Panasonic
213-092XX Patient Monitor, 12” , including SpO
2
probe
213-09350
Patient Monitor Panel PC 17”, including
SpO
2
probe
213-094XX SimMan Essential, Rugged Patient Monitor
PC`s Panasonic, including SpO
2
probe
212-18150
Sleeve Patient Monitor
212-18250
Sleeve Instructor PC
245-96050 Webcam
212-19650
Headset with microphone
PoWer cordS
260305
Power Cord (US)
260306
Power Cord (EUR)
260307
Power Cord (UK)
212-07050
External Battery Charger (2)
212-18650
Power Supply (110-240V)
Manikin PartS
213-00050
SimMan Essential (manikin only)
214-00050
SimMan Essential Bleeding (manikin only)
212-07650
Arm Adaptor Screw/bolt
212-11350
Arm bushing (left and right)
213-12050
Genitalia with fluid reservoir, male and female
212-12250
Battery manikin, internal (pkg. 2)
212-12350
Thigh-joint connector
212-12450
Battery clip, manikin internal
212-12550
Panel cover (left and right)
213-13050
Arm right, IV arm (no convulsion)
213-14050
Arm left, BP Arm complete (no convulsion)
212-14250
Arm Adaptor SimMan 3G/SimMan
213-15050
Leg right, complete (Essential)
214-15050 Leg right, complete (Essential Bleeding)
213-16050
SimMan Essential Leg left
213-20050
Eyelense Set, Inserts
381106
Rigid Teeth (1)
381107
Soft Teeth (1)
380460
Neutral Genitalia
213-12250 Urine tank replacement
213-13450
Syringe to prime and fill IV arm , Access
Modified clinical acceSSorieS
200-00550
Cuff Assey, BP
282100
Manual Defib Adapters
212-17050 SpO
2
probe with USB connector
SuPPort Material
213-19150
Directions for Use
213-19350
Quick Setup Guide, poster
Li-ion
SimMan Ess DFU_RevF.indd 81
18.07.12 14:20