CLINICAL FEATURES
65
simman essentiaL bLeeDing ciRcuLation anD fLuiDs tab
1
2
3
4
5
7
6
11
8
10
9
about the ciRcuLation tab
The settings of the
Circulation fluids settings and configuration
The possible circulation fluids settings and details of how to configure them are outlined below.
1 - 5 Pulses
Move slider to appropriate position.
NOTE: Moving the central pulse slider sets the overall limit for all pulses represented by the red horizontal lines.
6 - Total Bleeding Rate
Number in box shows total bleeding rate from both upper and lower ports in ml/min.
7 - Upper Port Bleeding
Click to place a check in the checkbox for port open (bleeding).
Move slider to the left or click the ‘–‘ button to decrease bleeding rate. Move slider to the right or click the ‘+’ button to increase
bleeding rate.
NOTE: The percentage shown in the box indicates the valve opening of the lower bleeding port. The percentage can also be entered
by typing the desired percentage into the box.
8 - Select upper port bleeding type
Select bleeding type using drop down menu.
• Venous
• Arterial
9 - Lower Port Bleeding
Click to place a check in the checkbox for port open (bleeding).
Move slider to left or click the ‘–‘ button to decrease bleeding rate. Move slider to right or click the ‘+’ button to increase bleeding rate.
NOTE: The percentage shown in the box indicates the valve opening of the lower bleeding port. The percentage can also be entered
by typing the desired percentage into the box.