Leak test mode, 2 leak test features, Leak test features – Heath Consultants GT Series User Manual
Page 43: Leak test ranges, Leak test mode -1, Leak test ranges -1 4.2 leak test features -1
4-1
LEAK TEST MODE
LEAK TEST MODE
This mode is for the technician to investigate odour or
leak complaints and to pinpoint the leak.
4.1 LEAK TEST RANGES
Leak Test mode will have the following ranges available
for normal operation:
0 2000 ppm CH
4
0 100% LEL (option to display as gas in air)
0 100% Vol Gas
0 2000 ppm CO (if fitted)
4.2 LEAK TEST FEATURES
Leak Test mode will have the following features available:
Audible / Visual PPM Ticker (Geiger) Indication -
(Option ON at switch-on)
Audible / Visual Gas Alarms
Backlight
Flashlight
Pump - can be toggled ON / OFF and will stop if
flow fault is detected
Max Display
Autoranging from ppm-LEL-Gas
4