5.3.2 Load factory defaults

To load factory defaults from serial interface use following commands.

Command:

FD

Response:

Applying settings to Matrix please wait.

Wait until you see following welcome message on terminal screen.

“Welcome to Hall Research HSM matrix.”

.”

(Note: After loading factory defaults Matrix will reset to default values as mentioned in

section 5.2.4 Factory Default Settings)

6. Telnet Interface

HSM Telnet interface is IP based command line interface to control and monitor

matrix. Only one (1) client is allowed to connect at a time through this interface and on

every new connection, old connection will be closed. Telnet connection timeout is set

to infinity or until user closes connection. Telnet authentication depends on

authentication status of web interface. If authentication is enabled, password will be

same as what used for web interface. User can also disable telnet interface from web

interface.