beautypg.com

1 general – Glow-worm 56/3 Back Boiler User Manual

Page 4

background image

4

221724B

1.6 Water System - Open Vented

This back boiler can be used on an unrestricted open vented
system with the water supply taken from a feed and
expansion cistern, having a head between 1m (3ft3in)
minimum and 27m (90ft) maximum.

Diagrammatic layouts of systems are shown in diagram 1.4
and 1.5.

1.7 Sealed Water System

A kit and instructions, part number 459033, is available to
enable the back boiler to be used on a sealed water
system.

Please give the serial number of the back boiler when
ordering the kit.

1.8 Hot Water Cylinder

The back boiler is suitable for open vented systems using an
indirect cylinder (including single feed self priming type). The
indirect cylinder must be fitted to the manufacturer’s
recommendations and the system must conform to the
requirements of the current issue of BS5546 and BS6700.

It is recommended that the indirect cylinder be fitted with
some form of temperature control.

1.9 Frost Protection

If the position of the back boiler is such that it may be
vulnerable to freezing it should be protected as specified in
the current issue of BS5422.

It is also recommended that a frost protection thermostat is
fitted.

1.10 Draining Tap

A draining tap must be provided at the lowest point of the
system which will allow the entire system, the back boiler
and hot water cylinder to be drained.

Draining taps shall be to the current issue of BS2879.

1.11 Safety Valve

A safety valve need not be fitted to an open vented system.

1 General

3013

FRONT

OPENING

CL

ALL DIMENSIONS IN MM

PREPARED
BASE

Y

X

TABLE 1

FIRE TYPE

Miami 3 BBU

37-047-04A

37-047-07A

Melody 3 BBU

37-047-06A

Black Ash 3 BBU

37-047-08

Brown Ember 3 BBU

37-047-02A

Saxony 3 BBU

37-047-09

G.C No.

X

Y

X

Y

Miami 3 BBU

642

698

750

836

Melody 3 BBU

642

698

750

836

Black Ash 3 BBU

700

660

840

890

Brown Ember 3 BBU

795

707

905

892

Saxony 3 BBU

700

625

840

860

6302

C

B 405 min.

A

PREPARED
BOILER
BASE

Diagram 1.2

FRONT OPENING

A

B

C

Miami 3 BBU

350

405 to 580 560 to 590

Melody 3 BBU

350

405 to 580 560 to 590

Black Ash 3 BBU

350

406 to 460 560 to 590

*Brown Ember 3 BBU 350

406 to 580 560 to 590

Saxony 3 BBU

350

406 to 460 560 to 590

TABLE 2

Dimensions
for minimum
flat area
(no fixtures)

FIRE TYPE

Dimensions
for fixture or
surround
protection
clearance

Teak Mahogany

1.12 Back Boiler Location

This back boiler MUST NOT be installed in a private garage
or in a room containing a bath or shower or in a room used
or intended to be used as sleeping accommodation.