Installation – Glow-worm Clearly Hybrid - Back-up Module System User Manual
Page 22

0020096317_01 - 08/10 - Glow-worm
- 20 -
INSTALLATION
12.3 "Thermostat / sensor" menu
• Using the buttons
,
select
Rmstat/sensor on the screen.
• Press the button
to confirm.
12.4 Thermostat(s)
• Using the buttons
,
select
Roomstat(s) on the screen.
• Press the button
to confirm.
• Using the buttons
,
select the area controlled by the
room thermostat.
• Press the button
to confirm.
On the room thermostat:
• Press the button
for 7
seconds.
• Enter the professional access code
(96).
• Via the installer menu > select > RF
> pairing.
• Press the room thermostat button
.
The control unit and the room
thermostat display “Connection finished
" on the respective screen.
If the message "Connection failed" is
displayed, press the button
and
repeat the operation.
• Repeat these operations for each
room thermostat (the zone number
is displayed on the thermostat at the
end of pairing).
• Press the button
twice.
12.5 Outdoor sensor
• Using the buttons
, select
Outdoor sensor on the screen.
• Press the button
to confirm.
• Using the buttons
,
select
Connection on the screen.
• Press the button
to confirm.
• Press the button on the outdoor
sensor to connect.
ON
1
Key
1 Outdoor sensor button
i
Once the sensor is detected, the message
«Connection completed» is displayed.
If unsuccessful, the message "Connection failure" is
displayed.
Press the button
and repeat the operation.
• Press the button
.
i
The External T°C Correction allows you to correct
the temperature measured by the outdoor sensor
(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).