Installation – Glow-worm Clearly Hybrid - Back-up Module System User Manual
Page 24

0020096317_01 - 08/10 - Glow-worm
- 22 -
INSTALLATION
12.7.1
Heating
b
The maximum heating output temperature must be
adjusted in accordance with the characteristics of
your installation.
• Using the buttons
,
select
Heating on the screen.
• Press the button
to confirm.
This menu allows you to adjust the
installation’s maximum heating output
temperature (value adjustable between
30 ° C and 80 ° C - factory setting:
73°C).
• Press the button
.
• Press the button
.
• Increase or decrease with the
buttons
to display the
desired value.
• Press the button
to confirm.
• Press the button
.
This menu allows you to select the
heating curve (value adjustable
between 0.2 and 4 - factory setting:
1.2), which allows you to obtain the
maximum heating demand for the usual
minimum outdoor temperature for the
region in which the sensor is installed.
• Using the buttons
,
select
Heating curve adjustment on
the screen.
• Press the button
twice.
• Increase or decrease with the
buttons
to display the
desired value(s).
• Press the button
to confirm.
b
Ensure that the heating curve setting is
compatible with the installation.
Heating curve
A
B
1
2
3
Key
1 Older properties with radiators
2 Standard/modern house with radiators
3 Highly insulated modern house with low temperature radiators
or underfloor heating
A Heating flow temperature (°C)
b external temperature
• Press the button
twice.
12.7.2
Domestic hot water
i
The lower the temperature of the hot water, the more
economical the heat pump.
This menu allows you to adjust the
maximum hot water temperature (value
adjustable between 35 °C and 65 °C -
factory setting: 65°C).
• Using the buttons
,
select
Hot water on the screen.
• Press the button
to confirm.
• Press the button
.
• Increase or decrease with the
buttons
to display the
desired value.
• Press the button
to confirm.
• Press the button
.
12.7.3
Cooling (*)
(*) Function not active for the UK