beautypg.com

Installation – Glow-worm Clearly Heat Pumps - Standalone Module System User Manual

Page 29

background image

0020096321_00 - 07/10 - Glow-worm

- 27 -

INSTALLATION

b

When venting is complete, close the different
heating circuit air vent.

10.8.2

Heating circuit adjustment

2

3

1

4

Key
1 Speed

control

2

Speed II (factory setting)

3 Speed

I

4 By-pass

screw

• Turn the control (1) to select pump speed I or I, in

accordance with the fl ow / pressure curve below.

• Depending on the design of the system the by-pass may

need further adjustment. It is adjusted clockwise to close and
anti-clockwise to open. This should be balanced to ensure
that it operates if the pump output is adjusted.

Hydraulic module pump fl ow / pressure curve

60

50

40

30

20

10

0

200

400

1000

800

600

1200 1400

B

2

1

4

3

Key
1

Speed 2, bypass closed

2

Speed 2, bypass opened

3

Speed 1, bypass closed

4

Speed 1, bypass opened

A

Available pressure (kPa)

B

Flow within the circuit (l/h)

10.8.3

Venting the HP circuit

The venting of the HP circuit allows you to purge any air in the
HP circuit.

i

If the domestic hot water cylinder option is installed
on the system, reposition the kit 3-way valve to the
AUTO position.

Ø14

A

B

1

3

4

1

2

Key
1 Air

trap

2

Ø 14 mm fl at wrench (Not included)

3 Hose
4

Container (Not included)

• Connect one end of the hose (3) to the trap (1).

• Insert the other end of the hose (3) into the container (4) in order

to recover any residual glycol during the venting of the circuit.

• Using the buttons

,

select Vent HP circuit on the screen.

• Press the button

to confi rm.

• Confi rm with the button

in

order to begin the venting process.

You can start the heating circuit bleed at
the same time.