INSTALLATION

9

Activating the room thermostat

1

2

3

Key
1 Battery

cover

2 Protective

cover

3 Room

thermostat

• Remove the protective cover (2) located in the battery

compartment following the order (A) to (C).

• The main screen of the room thermostat is displayed.

10 Activating the control unit

a

Ensure that the heat pump and heating circuits
have been fi lled.

e

Ensure that all the electrical connections have
been made.

• Switch ON the circuit breaker which is located on the

electrical panel and connected to the control unit.

1

Key
1

Switch On (I) / Off (O)

• Turn on the control unit (1) with the switch (2) in position (I).

When connected for the fi rst time, the installation menu is
displayed.

• Use the buttons

to select

a language.

• Press the button

to confi rm.

• Enter the installer access code 96

with the buttons

.

• Press the button

to confi rm.

10.1 Confi guring the installation

• Follow and confi rm the steps

prompted by the initial installation
aid.

• Press the button

to confi rm.

Your system corresponds to diagram
number "4" in the control unit.

• Choose diagram number "4" with the

buttons

.

• Press the button

to confi rm.

Multizone kit' refers to zone valves for
more than one heating zone.

• If so, choose "YES".

• Use the button

to confi rm and

follow the control unit instructions.

• If this is not the case and the

installation has only one zone, choose
"NO" with the buttons

.

• Press the button

to confi rm.