10.7.2
Domestic hot water
i
The lower the temperature of the hot water, the more
economical the heat pump.
This menu allows you to adjust the
maximum hot water temperature (value
adjustable between 35 °C and 65 °C -
factory setting: 65°C).
• Using the buttons
,
select Hot water on the screen.
• Press the button
to confi rm.
• Press the button
.
• Increase or decrease with the
buttons
to display the
desired value.
• Press the button
to confi rm.
• Press the button
.
10.7.3 Cooling
(*)
(*) Function not active for the UK
10.7.4 HP
Management
• Select
HP Management
on the
screen using the buttons
.
• Press the button
.
This menu is used to set the outside
temperature from which the heat pump
must turn off (value adjustable from
-10°C to 20°C, factory setting: 0°C).
• Press the button
.
• Increase or decrease with the
buttons
to display the
desired value.
• Press the button
.
This menu allows you to adjust the
installation’s maximum heating output
temperature (value adjustable between
30 ° C and 80 ° C - factory setting:
73°C).
• Press the button
.
• Press the button
.
• Increase or decrease with the
buttons
to display the
desired value.
• Press the button
to confi rm.
• Press the button
.
This menu allows you to select the
heating curve (value adjustable
between 0.2 and 4 - factory setting:
1.2), which allows you to obtain the
maximum heating demand for the usual
minimum outdoor temperature for the
region in which the sensor is installed.
• Using the buttons
,
select Heating curve adjustment on
the screen.
• Press the button
twice.
• Increase or decrease with the
buttons
to display the
desired value(s).
• Press the button
to confi rm.
b
Ensure that the heating curve setting is
compatible with the installation.
Heating curve
A
B
1
2
3
Key
1
Older properties with radiators
2
Standard/modern house with radiators
3
Highly insulated modern house with low temperature radiators
or underfl oor heating
A Heating
fl ow temperature (°C)
B External
temperature
• Press the button
twice.