Installation – Glow-worm Clearly Heat Pumps - Standalone Module System User Manual
Page 24
![background image](/manuals/736734/24/background.png)
0020096321_00 - 07/10 - Glow-worm
- 22 -
INSTALLATION
10.4 Thermostat(s)
• Using the buttons
,
select Roomstat(s) on the screen.
• Press the button
to confi rm.
• Using the buttons
,
select the area controlled by the
room thermostat.
• Press the button
to confi rm.
On the room thermostat:
• Press the button
for 7
seconds.
• Enter the professional access code
(96).
• Via the installer menu > select > RF
> pairing.
• Press the room thermostat button
.
The control unit and the room
thermostat display “Connection fi nished
" on the respective screen.
If the message "Connection failed" is
displayed, press the button
and
repeat the operation.
• Repeat these operations for each
room thermostat (the zone number
is displayed on the thermostat at the
end of pairing).
• Press the button
twice.
10.5 Outdoor
sensor
• Using the buttons
, select
Outdoor sensor
on the screen.
• Press the button
to confi rm.
• Using the buttons
,
select Connection on the screen.
• Press the button
to confi rm.
• Press the button on the outdoor
sensor to connect.
ON
1
Key
1
Outdoor sensor button
i
Once the sensor is detected, the message
«Connection completed» is displayed.
If unsuccessful, the message "Connection failure" is
displayed.
Press the button
and repeat the operation.
• Press the button
.
i
The External T°C Correction allows you to correct
the temperature measured by the outdoor sensor
(+/- 5 ° C, at intervals of 1 ° C - factory setting: 0).