FAULT: NO HEATING, BUT HOT WATER AT TAPS

Is the heating set high enough ?

Is the room thermostat in demand ?

The setting is too low or the boiler

is set to summer mode.

Turn the setting up by turning the

central heating temperature

control knob clockwise.

NO

Adjust the setting.

NO

Check the thermostat, the line,

the connections both

to the room thermostat and

the control board (PCB).

YES

YES

Check by overriding the room thermostat

at the connector. Does the fault persist ?

YES

Check the electrical connections

to the control board (PCB).

If the problem persists fit a

replacement control board (PCB).

NO

Is the system fitted with

a external sensor ?

YES

YES

YES

Unplug the sensor

and test it individually.

16 Fault Finding