16

2000225000B

70mm

65mm

410 mm

Max. Std flue length 930mm

Min. Std flue length 300mm

205mm

20mm
Min. Clearance

75mm
Min. Wall Thickness

SIDE FLUE

10093

Diagram 10.1

The

Telescopic flue,

(adjustable without

cutting) is suitable for installations that
require a flue length from 425 minimum to
659.5 maximum. There are no extensions or
bends available for this flue.

The

Standard flue, suitable for side only,

(adjustable by cutting) is suitable for
installations that require a flue length from
300 minimum to 930 maximum (without
extensions).

Note: Additional 1 metre extentions, 90° and 45° bends are
available. The maximum extended flue is 3m. The use of flue
bends requires the flue lengths to be reduced by 1m. for 90° and
0.5m. for 45°.

The boiler is only suitable for top outlet flue connection.

10.1 Top outlet flue
Telescopic kit A2004500, Standard kit 86285

10.2 Flue systems rear

Telescopic Flue

Extend to suit flue length required.

10091

Diagram 10.2

10 Flue Installation Telescopic and Standard

10.3 Flue systems side

Telescopic Flue

Extend to suit flue length required.

Standard Flue, Refer to diagram 10.1.

10.4 Flue cutting.

Telescopic Flue

The telescopic flue cannot be cut.

Standard Flue, refer to diagram 10.2.

Important: Do not leave any burrs or sharp edges on the cut
ends of the pipes.

17mm

160mm

X

cutting length

C

Air duct cutting length

X minus 160mm

plus 17mm =

Air duct

cutting length

95mm

check

dimension

(cut end)

Flue duct cutting length =
air duct cutting length + 152mm

L

Air duct

Flue duct

Outside

wall face