beautypg.com

Error injection – EXFO FTB-8100 Series Transport Blazer for FTB-500 User Manual

Page 512

background image

Common Tabs

498

FTB-8100 Series Transport Blazer

TCM TX

Error Injection

Allows manual or automated error injection.

³

Type: The following error types are available with both manual and
automated injection modes. The default setting is TC-IEC for HOP and
TC-BIP for LOP.

TC-IEC (Tandem Connection - Incoming Error Count): Available for
HOP only. Bits 1 to 4 of the N1 byte.

TC-BIP (Tandem Connection - Bit Interleaved parity): Available for LOP
only. Bits 1 and 2 of the Z6/N2 byte contain the BIP-2 computation of
the payload.

TC-REI (Tandem Connection - Remote Error Indication): Bit 5 of N1 or
Z6/N2 byte is set to 1.

OEI (Outgoing Error indication): Bit 6 of the N1 or Z6/N2 byte is set to 1.

³

Amount: Select the amount of error to be generated. Choices are 1
through 50. The default setting is 1.

³

Send button: Press Send to manually generate error(s) according to
the Error Type and the Amount of Errors selected.

³

Rate: Press Rate to select the injection rate for the selected error.
Choices and default setting depend on the test path.

³

Continuous: When activated, generates the selected error to its
theoretical maximum rate. This setting is disabled by default.

³

On/Off button: The On/Off button is used to activate/deactivate the
selected automated error at the rate specified or continuously when
continuous is enabled. This setting is disabled (Off) by default.