EXFO FTB-8100 Series Transport Blazer for FTB-500 User Manual
Page 105

Creating and Starting a Test Case
SONET/SDH Application
91
Typical Test Cases
Creating an Optical SONET/SDH/OTN Multi-Channel
SDT Test Case (FTB-8120/8130/8140)
The following procedure describes an optical SONET/SDH/OTN
Multi-Channel test case on the FTB-8120, FTB-8120NG, FTB-8120NGE,
FTB-8130, FTB-8130NG, FTB-8130NGE, and FTB-8140 modules.
To create an Optical SONET/SDH/OTN Multi-Channel Test:
1. Test configuration:
1a. Select Multi-Channel SDT as the Test Mode.
Refer to Test Configuration on page 126 for
more information.
1b. Press Next.
1c. The Optical port is automatically selected.
Press Next.
2. Interface selection:
2a. Press the desired interface: OC-3, OC-12, OC-48, OC-192,
OC-768, STM-1, STM-4, STM-16, STM-64, STM-256, OTU1, OTU2,
OTU3. Choices depend on the rates available on the module.
3. Press Finish to complete the test setup. The Grid tab closes and
automatically switches to the SDT - Monitor tab.
4. For additional configuration parameters and results, refer to Summary
Tabs on page 125 and Service Disruption Time (SDT) - Results on
page 421.
5. Press the Start button to start the test. Refer to Global Test Status and
Controls on page 35 for more information on test management.