EXFO FTB-8100 Series Transport Blazer for FTB-500 User Manual

Page 113

background image

Creating and Starting a Test Case

SONET/SDH Application

99

Typical Test Cases

4. TCM Configuration:

4a. Select ODU TCM (TCM1 to TCM6) layers as

required

4b. Press Next or Finish.

5. Select the test Path/Mapping:

5a. From the data path selector, select the desired

path/ mapping. See Supported Paths/Mappings on page 59 for
more information.

5b. For ODU2, select ODU TCM (TCM1 to TCM6)

layers as required.

Select a group of four OPU3 tributary slots.
Choices are 1 to 16:

When the Fixed Structure check box is
selected, the selection of a tributary slot will
automatically select four tributary slots (from
the same column) which constitute the
foreground traffic. Choices are (1,5,9,13), (2, 6,
10, 14), (3, 7, 11,15), and (4, 8, 13, 16). Note that
the Tributary Port number is automatically assigned.

When the Fixed Structure check box is cleared, select the four
tributary slots individually, and select the Tributary Port number
(1, 2, 3, or 4) that will be associated to the selected tributary slots.