SONET Tabs

220

FTB-8100 Series Transport Blazer

Section RX (SONET)

J0 Trace

³

Received Message: Displays the received J0 value. The
represents the CRC-7 for a 16-bytes format. The last two bytes of a
64-bytes format,

R

> and

F

>, represent respectively a carriage

return and a line feed.

³

Enable TIM-S (Trace Identifier Mismatch - Section): Allows enabling
the Trace Identifier Mismatch for the expected message defined.
Enable TIM-S has to be enabled to give access to the expected trace
format and message.

³

Expected Message: Allows entering the expected J0 Trace message. J0
value should be ASCII suitable characters. The default message is
EXFO SONET/SDH for 16 bytes and EXFO SONET/SDH Analyzer
Section/RS trace test message
for 64 bytes.

³

Expected Format: Allows the selection of the expected format: 16 or