beautypg.com

Technical specifications, Otdr, Ftb-720g otdr technical specifications – EXFO FTB-700 for FTB-1 User Manual

Page 299: Ftb-730g otdr technical specifications

background image

Technical Specifications

OTDR

291

Note: The following specifications are for the OTDR instrument. Refer to the

Transport Application user guide for specifications on OTN, SONET/SDH,
and DSn/PDH test applications. Refer to the Ethernet/Packet
Sync/FC/Wireless user guide for specifications on Ethernet, Packet Sync,
Fibre Channel, and Wireless test applications.

FTB-720G OTDR TECHNICAL SPECIFICATIONS

Wavelength (nm)

b

1310 ± 20, 1550 ± 20

Dynamic range

(dB)

c

36, 34

Event dead zone (m)

d

0.8

Attenuation dead zone (m)

d

5

Distance range (km)

1.25, 2.5, 5, 10, 20, 40, 80, 160, 260

Pulse width (ns)

5, 10, 30, 50, 100, 275, 500, 1000, 2500, 10 000, 20 000

Linearity (dB/dB)

b

±0.03

Loss threshold (dB)

0.01

Loss resolution (dB)

0.001

Sampling resolution (m)

0.04 to 5

Sampling points

Up to 256 000

Distance uncertainty (m)

e

±(0.75 + 0.0025 % × distance + sampling resolution)

Measurement time

User-defined (60 min. maximum)

Typical real-time refresh (Hz)

3

Stable source output power (dBm)

f

–7

NOTES

a.

All specifications valid at 23 °C ± 2 °C with an FC/PC connector, unless otherwise specified; APC connector for FTB-720G and FTB-730G singlemode model.

b. Typical.

c. Typical dynamic range with longest pulse and three-minute averaging at SNR = 1.

d.

Typical dead zone for reflectance below –45 dB, using a 5 ns pulse.

e. Does not include uncertainty due to fiber index.

f. Typical output power is given at 1550 nm.

g. Non-reflective FUT, non-reflective splitter, 13 dB loss, 50 ns pulse, typical value.

FTB-730G OTDR TECHNICAL SPECIFICATIONS

Wavelength (nm)

b

1310 ± 20/1550 ± 20

Dynamic range (dB)

c

39/37

Event dead zone (m)

d

0.8

Attenuation dead zone (m)

d

4/4.5

Distance range (km)

1.25, 2.5, 5, 10, 20, 40, 80, 160, 260, 400

Pulse width (ns)

5, 10, 30, 50, 100, 275, 500, 1000, 2500, 10 000, 20 000

Linearity (dB/dB)

b

±0.03

PON dead zone (m)

g

35

Loss threshold (dB)

0.01

Loss resolution (dB)

0.001

Sampling resolution (m)

0.04 to 5

Sampling points

Up to 256 000

Distance uncertainty (m)

e

±(0.75 + 0.0025 % x distance + resolution)

Measurement time

User-defined (60 min. maximum)

Typical real-time refresh (Hz)

4

Stable source output power (dBm)

f

–2.5

Reflectance (dB)

b

±2