Analyzing Traces with the Bidirectional Analysis Application (Optional)

OTDR

233

Deleting Events

Deleting Events

Note: You can only delete events from the A->B or B->A trace (not from the

bidirectional measurement). The application regenerates the bidirectional
measurement automatically to take into account the modifications you
have made.

Almost any element can be deleted from the events table, except:

end of analysis

fiber section

launch level

end of fiber

span start

span end

I

MPORTANT

The only way to “recover” deleted items is to reanalyze the trace.
For more information, see Reanalyzing Traces and Regenerating the
Bidirectional Measurement