beautypg.com

A technical specifications, Mportant, Multifunction loss tester – EXFO FTB-3930 MultiTest User Manual

Page 93: Technical specifications

background image

Multifunction Loss Tester

87

A Technical Specifications

I

MPORTANT

The following technical specifications can change without notice.
The information presented in this section is provided as a reference
only. To obtain this product’s most recent technical specifications,
visit the EXFO Web site at www.exfo.com
.

TECHNICAL SPECIFICATIONS

External Power Meter

FTB-3932

FTB-3932X

FTB-3933

Detector type

Ge

GeX

InGaAs

Measurement range (dBm)

10 to –70

26 to –55

6 to –73

Uncertainty

b, c

± 5 % ± 0.1 nW

± 5 % ± 3 nW

± 5 % ± 0.05 nW

Wavelength range (nm)

800 to 1650

800 to 1650

800 to 1650

Display resolution

b

(dB)

0.01

0.01

0.01

Calibrated wavelengths

40

42

40

Recommended recalibration
period (years)

3

3

3

Automatic offset nulling

d

Yes

Yes

Yes

Measurement-distance units

kilometers, meters, kilofeet, feet, miles

Sources

Standard

–4

–5

–12C (second port)

–12D (second port)

Wavelengths

e

(nm)

1310 ± 20
1550 ± 20

1310 ± 20
1550 ± 20
1625 ± 10

1310 ± 20
1490 ± 10
1550 ± 20

850 ± 25
1300 +50/–20

850 ± 25
1300 +50/–20

Emitter type

Laser

Laser

Laser

LED

LED

Minimum output power

e

(dBm)

–1/–1

–1/–4/–7

–1/–7/–4

–27/–27 (50/125 μm)

i

–21/–21 (62.5/125 μm)

i

Spectral width

f

(nm)

) 5/) 5

) 5/) 5/) 5

) 5/) 5/) 5

50/135

50/135

Stability

g

(8 hours) (dB)

± 0.05

± 0.05

± 0.05

± 0.05

± 0.05

FasTesT

Standard

–4

–5

–12C (second port)

–12D (second port)

Wavelengths (nm)

1310
1550

1310
1550
1625

1310
1490
1550

850
1300

850
1300

Loss range

h

(dB)

60

56

56

40

46

Loss precision

i

(repeatability) (dB)

side-by-side
loopback

0.15
0.25

0.15
0.25

0.15
0.25

0.15
0.25

0.15
0.25

Length measurement
range (km)

200

200

200

5

5

Length measurement
uncertainty (typical)

j

± (10 m + 1 % x length)