Performing Automated IL/ORL/Length Measurements (FasTesT)

Multifunction Loss Tester

43

Performing the FasTesT

Performing the FasTesT

Although F

AS

T

ES

T requires two units (one at each end of the fiber under

test), you initiate it from only one (the master). Both units use F

AS

T

ES

T

settings from the master unit.

To perform a FasTesT:

Unit A (Master)

Unit B

1. If necessary, null the offsets (see

Nulling Electrical Offsets on page 22).

1. If necessary, null the offsets.

2. Clean your fibers properly (see

Cleaning and Connecting Optical
Fibers
on page 12).

2. Clean your fibers properly.

3. Set up the F

AS

T

ES

T (see Setting Up the

FasTest on page 36).

4. If you are testing ORL, perform an

ORL zero measurement from the ORL
Meter
pane (see Performing ORL
Reference and Setting ORL Zero Value

on page 30).

3. If you are testing ORL, perform an

ORL zero measurement from the ORL
Meter
pane.

5. Reference your unit (see Referencing

Units for FasTesT on page 38).

4. Reference your unit.