beautypg.com

Ma module start/stop or pwm transducer wiring – Delta RMC70 User Manual

Page 33

background image

Appendix A: Wiring

deltamotion.com

31

MA Module Start/Stop or PWM Transducer Wiring

For magnetostrictive transducers with Start/Stop or PWM outputs.

12-pin Axis
Connector

Interrogate +

Interrogate -

Return +

Return -

Power Supply

+Pwr

Cmn

Int/Clk+

Int/Clk-

Cmn

Ret/Dat+

Ret/Dat-

Case

Pwr+

DC Ground

Tip: See next page for manufacturer-specific wiring diagrams.

Notes:

The MA module interfaces to 5V differential (RS-422) signals.
Single-ended (TTL) transducers are not supported.

The Cmn pins on the 12-pin connector are electrically identical.

The user must supply power to the transducer.

Do NOT connect the transducer ground or common to the
shield, case, or protective earth ground.