Step 9: Connect Feedback Device

deltamotion.com

17

MA Module–Start/Stop or PWM

1. In the Axis Parameters, on the

Setup tab, set the Feedback
Type
to MDT.

2. Set the MDT Type register to

the type of MDT transducer
you have. This information is
available on the transducer
datasheet.

3. Click the Download button

to apply the changes to the RMC.

4. Continue to the Verify Feedback section on page 19.

MA Module–SSI

1. In the Axis Parameters pane,

on the Setup tab, set the
Feedback Type to SSI.

2. From the information in your

SSI data sheet, set the
following parameters:

SSI Format

SSI Data bits (e.g. 24)

Linear/Rotary

Note: For help on a parameter, click the cell and press F1.

3. Click the Download button

to apply the changes to the RMC.

4. Continue to the Verify Feedback section on page 19.