AT Command Set and S-Registers

14-25

3910-A2-GN32-40

September 1998

Table 14-3

(11 of 13)

391x Series S-Registers

S-Register

DCP LCD

Command

Sequence

Description

S89

V.42 Automatic Request for Retransmission (ARQ) Window Size
Increase. Register allows the ARQ window size to be set to a value
from six frames to fifteen frames.

For best performance, this register should remain at its default setting
of six frames (ATS89 = 0). The only reason to change it is for satellite
delays.

Register has the following values:

0 = six frames
1 = seven frames
2 = eight frames
3 = nine frames
4 = ten frames
5 = eleven frames
6 = twelve frames
7 = thirteen frames
8 = fourteen frames
9 = fifteen frames

The factory setting is 0 (six frames).

This command only applies when the modem connects using V.42bis
data compression or V.42 error control. If the modem is configured for
Direct mode, MNP mode, Buffer mode, or Synchronous operation, this
command is invalid.

This command does not have a front panel equivalent.

S90

DTE Rate = VF. Register allows the DTE’s data rate to be equal to the
VF (telephone line) data rate. If Enabled, the data rate between the
DTE and modem is the same as the modem’s VF data rate. As a
result, when the modem is in Data mode, the speed of the data
passed between the modem and DTE occurs at the VF data rate.

Register has the following values:

0 = Disable
1 = Enable

The factory setting is Disable.

Configure\Edit\
DTE Interface

S92

V.29 Train On Data. When enabled, the modem receiver can train
based upon the incoming data or a training sequence from the distant
modem. This function is necessary for a remote (tributary) modem in a
V.29 multipoint network and is recommended for a control modem as
well.

Register has the following values:

0 = Disable
1 = Enable

The factory setting is Disable.

Configure\Edit\
Leased