391x Series S-Registers

S-Register

DCP LCD

Command

Sequence

Description

S53

V.54 Address. Identifies the address of the modem to be placed in a
loopback test.

Register has the following values:

0 = Disable

1–34 = Modem address

The factory setting is Disable.

Configure\Edit\
Tests

S54

V.54 Device Type. Identifies where the modem is physically located in
the network.

Register has the following values:

0 = Peripheral
1 = Intermediate

The factory setting is Peripheral.

Configure\Edit\
Tests

S55

Access From Remote. Register determines if a modem’s DCP can be
accessed by a remote modem.

Register has the following values:

0 = Enable
1 = Disable

The factory setting is Enable.

Configure\Edit\
Misc

S56

Remote Access Password. Register allows entry of the first pair
(leftmost) of digits of a remote access password. Any value from 00 to
99 is valid. For example, if the remote access password is 12345678,
then S56 = 1 and 2.

Configure\Edit\
Misc

S57

Remote Access Password. Register allows entry of the second pair of
digits of a remote access password. Any value from 00 to 99 is valid.

Configure\Edit\
Misc

S58

Remote Access Password. Register allows entry of the third pair of
digits of a remote access password. Any value from 00 to 99 is valid.

Configure\Edit\
Misc

S59

Remote Access Password. Register allows entry of the fourth pair
(rightmost) of digits of a remote access password. Any value from 00
to 99 is valid.

Configure\Edit\