Installation – Desa GA3700 User Manual
Page 9
![background image](/manuals/73429/9/background.png)
www.desatech.com
113109-01G
9
Figure 5 - Installing Hood to Firebox
Note: Your fireplace is designed to be used in
zero clearance installations. Wall or framing ma-
terial can be placed directly against any exterior
surface on the rear, sides or top of your fireplace,
except where standoff spacers are integrally at-
tached. If standoff spacers are attached to your
fireplace, these spacers can be placed directly
against wall or framing materials.
Use the dimensions shown for rough openings
to create the easiest installation. See Built-In
Fireplace Installation, page 12.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
fireplace in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion, page 6.
IMPORTANT: Make sure the fireplace is level.
If fireplace is not level, log set will not work
properly.
CHECK GAS TYPE
Use the correct gas type (natural or propane/
LP) for your fireplace. If your gas supply is not
correct, do not install fireplace. Call dealer
where you bought fireplace for proper type
fireplace.
WARNING: This appliance is
equipped for either natural gas
or propane/LP gas but not both.
Gas type is indicated on the rat-
ing plate. Field conversion is not
permitted.
ELECTRICAL HOOKUP
(Models GA3700 Series and GA3700T
Series Blower Accessories and GA3555
Internal Duplex Kit)
This fireplace accepts a blower assembly with
an electrical cord. The electrical cord is five feet
in length. You must locate fireplace within reach
of a 120 volt grounded electrical outlet. If not,
you must install an electrical outlet within reach
of fireplace power cord. The GA3555 outlet
accessory is used for built-in applications with
blower accessory installed.
INSTALLING HOOD
Install hood to top of firebox as shown in
Figure 5. Use 3 Phillips screws provided.
INSTALLATION
Continued
Figure 6 - Assembling Perimeter Trim
Side Trim
Top
Trim
Slot
Mitered
Edge
Slot
Shim
Set Screws
Adjusting
Plate
ASSEMBLING AND ATTACHING
OpTIONAL pERIMETER TRIM
(Included with Mantel Accessory)
IMPORTANT: If you are recessing the fire-
box in a wall, do not attach perimeter trim at
this time. See Built-In Fireplace Installation,
page 12.
Note: The instructions below show assembling
and attaching perimeter trim to fireplace.
1. Remove packaging from three pieces of
perimeter trim.
2. Locate four perimeter screws, two adjust-
ing plates with set screws and two shims
in the hardware packet.
3. Align shim under adjusting plate as shown
in Figure 6.
4. Slide one end of adjusting plate/shim in
slot on mitered edge of top perimeter trim
(see Figure 6).
5. Slide other end of adjusting plate/shim in
slot on mitered edge of side perimeter trim
(see Figure 6).
6. While firmly holding edges of perimeter trim
together, tighten both set screws on the
adjusting plate with slotted screwdriver.