beautypg.com

Installation, Continued built-in fireplace installation – Desa GA3700 User Manual

Page 12

background image

www.desatech.com

113109-01G

12

INSTALLATION

Continued

BUILT-IN FIREpLACE INSTALLATION

Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure.
This makes the front of fireplace flush with
wall. If installing a mantel above the fireplace,
you must follow the clearances shown in Fig-
ure 16, page 13. Follow the instructions below
to install the fireplace in this manner.

Actual

Framing

Height

32

3

/

8

"

33"

Front Width

34

5

/

16

"

35

1

/

2

"

Depth

16

11

/

16

"

17

3

/

4

"

1. Frame in rough opening. Use dimensions

shown in Figure 13 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 14 for the rough opening.
The height is 33" which is the same as the
wall opening above.

2. If using blower, install and properly ground

GA3555, three-prong 120 volt electrical
outlet, in fireplace. Follow instructions in-
cluded in kit (see Accessories, page 34).

3. Install gas piping to fireplace location. This

installation includes an approved flexible
gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible
gas line must be the last item installed on
the gas piping. See Installing Gas Piping
to Fireplace Location,
page 13.

4. Carefully set fireplace in front of rough

opening with back of fireplace inside wall
opening.

5. Plug electrical cord into electrical outlet

installed in step 2.

6. Carefully insert fireplace into rough

opening.

7. Attach flexible gas line to gas supply.

See Connecting Fireplace to Gas Supply,
page 15.

8. Attach fireplace to wall studs using nails

or wood screws through holes in nailing
flange (see Figure 15).

9. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

10. Install perimeter trim after final finishing

and/or painting of wall (see Figure 7,
page 10 ).

35

1

/

2

"

17

3

/

4

"

33"

Figure 13 - Rough Opening for Installing

in Wall

39

3

/

8

"

27

7

/

8

"

55

5

/

8

"

35

1

/

2

"

Figure 14 - Rough Opening for Installing

in Corner

Figure 15 - Attaching Fireplace to Wall

Studs

Nailing
Flanges

Nails or
Wood
Screws

This manual is related to the following products: