beautypg.com

Installation – Desa GA3700 User Manual

Page 15

background image

www.desatech.com

113109-01G

15

INSTALLATION

Continued

CONNECTING FIREpLACE TO GAS
SUppLY

Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

1. Remove fireplace screen. Remove two

screws that hold fireplace screen in place
for shipping. These screws are located
near top of screen. Discard screws. Lift
fireplace screen up and pull out to re-
move.

2. Remove screws that attach log base

assembly to fireplace. Carefully lift up
log base assembly and remove from
fireplace. See Figure 19.

Note: If adding the G8005 series brick liner
accessory, install it now. Follow instructions
in G8005 accessory kit.

CAUTION: Do not pick up

log base assembly by burner.

This could damage burner. Only

handle base by grates.

3. Route gas line (provided by installer)

from equipment shutoff valve to fireplace.
Route flexible gas supply line through one
of the access holes.

Figure 19 - Removing Log Base

Assembly From Fireplace

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 24).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

4. Attach the flexible gas line to gas supply.

Check tightness of flexible gas line at-
tached to gas regulator of fireplace. See
Figure 20.

5. Check all gas connections for leaks. See

Checking Gas Connections.

6. Replace log base assembly back into

fireplace. Feed flexible gas line into fire-
place base area while replacing log base
assembly. Make sure the entire flexible
gas line is in fireplace base area. Reat-
tach log base assembly to fireplace with
screws removed in step 2.

Figure 20 - Attaching Flexible Gas Lines

Together

Flexible Gas Line
from Fireplace
Gas Regulator

To Fireplace Gas
Regulator

Equipment Shutoff Valve
Provided by Installer

Propane/LP
To External
Regulator

Natural Gas
To Gas Meter

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply a noncorrosive leak detec-

tion fluid to all joints. Bubbles

forming show a leak. Correct all

leaks at once.