beautypg.com

Troubleshooting – Desa GA3700 User Manual

Page 26

background image

www.desatech.com

113109-01G

26

TROUbLEShOOTING

Continued

pOSSIBLE CAUSE

1. Control knob not fully

pressed in

2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching

thermocouple, which allows
thermocouple to cool, caus-
ing pilot flame to go out. This
problem could be caused by
one or both of the following:

A) Low gas pressure
B) Dirty or partially clogged

ODS/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged
7. Control valve damaged

1. Inlet gas pressure is too

low

2. Burner orifice(s) clogged

3. Thermopile leads disconnect-

ed or improperly connected

4. Burner will not come on in

remote position

1. Manifold pressure is too

low

2. Burner orifice(s) clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufac-

turing processes and logs
curing

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30
seconds

3. Fully open equipment shut-

off valve

4. A) Contact local natural or

propane/LP gas company


B) Clean ODS/pilot (see

Cleaning and Maintenance,
page 24) or replace ODS/
pilot assembly

5. Hand tighten until snug,

then tighten 1/4 turn more

6. Replace pilot assembly
7. Replace control valve

1. Contact local natural or

propane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 24)
or replace burner orifice(s)

3. Reconnect leads (see Wir-

ing Diagram, page 29)

4. Replace battery in transmit-

ter and receiver

1. Contact local natural or

propane/LP gas company

2. C l e a n b u r n e r ( s ) ( s e e

Cleaning and Maintenance,
page 24) or replace burner
orifice(s)

1. Clean burner (see Cleaning

and Maintenance, page 24)
or replace burner orifice(s)

2. Replace damaged burner
3. Replace gas regulator

1. Check burner for dirt and

debris. If found, clean
burner (see Cleaning and
Maintenance
, page 24)

2. Replace gas control
3. Problem will stop after a few

hours of operation

OBSERvED pROBLEM

ODS/pilot lights but flame
goes out when control knob
is released

Burner does not light after
ODS/pilot is lit

Delayed ignition of one or
both burners

Burner backfiring during
combustion

Slight smoke or odor during
initial operation

This manual is related to the following products: