Product identification, Safety – Desa GA3700 User Manual
Page 4
www.desatech.com
113109-01G
4
SAFETY
Continued
system. The ODS shuts down the fireplace
if enough fresh air is not available. See Air
for Combustion and Ventilation, page 6. If
fireplace keeps shutting off, see Trouble-
shooting, page 25.
10. Do not run fireplace
• where flammable liquids or vapors are
used or stored
• under dusty conditions
11. Do not use this fireplace to cook food or
burn paper or other objects.
12. Do not use fireplace if any part has been
exposed to or under water. Immediately
call a qualified service technician to in-
spect the fireplace and to replace any part
of the control system and any gas control
which has been under water.
13. Do not operate fireplace if any log is
broken. Do not operate fireplace if a log
is chipped (dime-sized or larger).
14. Turn fireplace off and let cool before
servicing. Only a qualified service person
should service and repair fireplace.
15. Operating fireplace above elevations of
4,500 feet could cause pilot outage.
16. To prevent performance problems in
propane/LP units, do not use propane/
LP fuel tanks of less than 100 lbs. ca-
pacity (propane/LP units only).
17. Provide adequate clearances around air
openings.
Figure 1 - Log Base Assembly
Piezo
Ignitor
Optional
Remote
Control
Control
Knobs
Firebox
Hood
Firebox
Support
Log Set
Remote Selector
Switch (Optional)
Top Outer
Casing
Blower Assembly
(Optional)
Screen
Assembly
Figure 2 - Fireplace
Louver
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do
not use any phone in your building
• immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions
• if you cannot reach your gas supplier,
call the fire department
4. This fireplace shall not be installed in a
bedroom or bathroom.
5. Do not use this fireplace as a wood-burn-
ing fireplace. Use only the logs provided
with the fireplace.
6. Do not add extra logs or ornaments such
as pine cones, vermiculite or rock wool.
Using these added items can cause soot-
ing. Do not add lava rock around base.
Rock and debris could fall into the control
area of fireplace.
7. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 24.
8. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
9. This fireplace needs fresh air ventilation to
run properly. This fireplace has an Oxygen
Depletion Sensing (ODS) safety shutoff
PRODUCT IDENTIFICATION