beautypg.com

Operation – Desa GA3700 User Manual

Page 20

background image

www.desatech.com

113109-01G

20

O

F

F

PIL

OT

LO

IH

AUTO
OFF
ON

O

N

Figure 32 - Control Knob and Ignitor

Button Location (Shown as Supplied, No

Control Options)

Control Knob

Ignitor Button

Selector Switch

Flame Adjustment
Knob

4. Press in and turn control knob clockwise

to the OFF position.

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information, page 19. If you
don’t smell gas, go to the next step.

6. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds
(see Figure 32).

Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.

7. With control knob pressed in, press and

release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.

Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure,
page 21.

8. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob.

• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4
through 8.

9. Slightly push in and turn control knob coun-

terclockwise

to the ON position.

10. Wait one minute and switch selector

switch to the ON position to light burner.

Figure 33 - Pilot (Propane/LP)

Ignitor
Electrode

Pilot Burner

Figure 34 - Pilot (Natural)

Pilot Burner

Ignitor
Electrode

OPERATION

Continued

11. Set flame adjustment knob to any level

between HI and LO.

12. To leave pilot lit and shut off burners only:

turn control knob clockwise

to the

PILOT position, or use remote control
manual OFF button, or set selector switch
in the OFF position.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

WARNING: Make sure the

selector switch is in the OFF

position when you are away from

home for long periods of time.

Fireplace will come on automati-

cally with selector switch in the

ON position.

TO TURN OFF GAS

TO AppLIANCE

1. Turn control knob clockwise

to the

OFF position.

2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set

selector switch in the OFF position to keep
from draining the battery.

3. Close equipment shutoff valve (see Fig-

ure 21, page 16).