AMT Datasouth 2012 M6 Plus User Manual
Page 55

Bline Size
0024 dot
2. Press the
button to move the
cursor from left digit to right digit, and press
the
button to set the value from “0” to
“9” and the “dot/ mm/ inch”. Press the
button to set the bline size into the
printer.
Bline Mode
Scan Mark
Intensity x
Ref. Level xxx
3. Open the print head mechanism, put the black
mark under the media sensor. Press the
button to set the value into the
printer.
Bline Mode
Scan Paper
Intensity x
Ref. Level xxx
4. Then, put the label without black mark under
the media sensor. Press the
button to set the value into the printer.
Note:
Normally, the value of “Ref. Level” for mark should be larger than paper for over
128. If the media sensor fails to do so, you have to manually change the
Intensity by pressing
and
to reach the above value.
Bline Mode
Complete
Intensity x
Ref. Level xxx
5. The bline sensor calibration is complete.
Press the
button the LCD screen
will return to the previous menu.
Media sensor
Black mark
Media sensor
Label without black mark
49