AMT Datasouth 2012 M6 Plus User Manual
Page 54
![background image](/manuals/733865/54/background.png)
B. Bline Mode
Press the
and
buttons to scroll the cursor to the sensor type. Press the
button to enter the black-mark sensor calibration mode.
48
B-1 Automatic
When enter the [Automatic] option, you will see following message
and printer will feed
the black mark label to calibrate the sensor sensitivity automatically. When calibration
process is completed, the LCD screen will return to the previous menu.
B-2 Manual
In case “Automatic” sensor calibration cannot apply to the media, please use “Manual”
function to calibrate the bline sensor manually.
When enter [Manual] option, you will see following message. Please complete there
steps
:
Paper Len.
00151 dot
1. Press the
button to move the
cursor from left digit to right digit, and press
the
button to set the value from “0” to
“9” and the “dot/ mm/ inch”. Press the
button to set the paper length into
the printer.
Calibration 2/4
Gap Mode
>
Bline Mode
Cont. Mode
Bline Mode 1/4
>
Automatic
Manual
Pre-Printed
Bline Mode
Automatic
Bline Mode 2/4
Automatic
>
Manual
Pre-Printed