Door gasket specifications, Figure 5: 400 door glass/gasket replacement, Gasket length quantity description – American Energy Systems Universal Doors User Manual
Page 19
Version 1.0c
9
DOOR GASKET SPECIFICATIONS
GASKET
LENGTH
QUANTITY
DESCRIPTION
500 DOOR SYSTEMS
PP-88, both left & right glass
50 1/8”
2
¾” wide by 1/16” thick tape
PP-815, Left doorframe
49”
1
3/8” diameter rope, high density
PP-815, Right doorframe
67”
1
3/8” diameter rope, high density
400 DOOR SYSTEMS
PP-88, both left & right glass
42”
2
¾” wide by 1/16” thick tape
PP-87, Left doorframe
42”
1
3/4” diameter rope, high density
PP-87, Right doorframe
63”
1
3/4” diameter rope, high density
NOTE:
(1) ALL door rope gaskets are high density material to ensure proper seal.
(2) All model door glass air wash systems require no glass tape (PP-88) to be installed along horizontal top edge of
glass for both left and right door glass.
(3) NO tempered or standard glass is to be used as replacement glass. Use proper replacement glass.
RIGHT 400 DOOR BACK VIEW
RIGHT 400 DOOR GLASS
GLASS TAPE
THREE SIDES
NO GLASS TAPE
AIR WASH SIDE
DOOR ROPE INSULATION
FOUR SIDES
GLASS
CLIP
BRASS TRIM
SCREW HOLE
GLASS
CLIP
GLASS
CLIP
GLASS
CLIP
GLASS
CLIP
NOT
USED
AIR
WASH
INSTALL GLASS
FIGURE 5: 400 DOOR GLASS/GASKET REPLACEMENT