APPENDIX C: TECHNICAL SPECIFICATIONS

Fuel Type:

#2 Yellow Shelled Corn Fuel (CLEANED)

Hardwood Pellet Fuel

Moisture Content: 14% or less (10- 12% preferred)

A.P.F.I. residential fuel

Heat

Content:

10,000

Btu/lb*

Heat

Content:

8200

BTU/lb

Ash

Content:

3%

maximum Ash

Content:

1%

max

Bulk Density: 40 lb./cubic ft. min

Moisture Content: 8% max

Size:

1/4”

to

3/8”

diameter

1.5” long max

Fines: 1% max through 1/8

th

screen

Hopper Size:

72 pounds corn or 55 pounds wood pellets


Flue Size:

4” recommended. If less than 10 feet use of 3 inch pipe is approved.


Flue Type:

PL double wall vent with stainless steel inner liner


Air Inlet:

3 inch by .15 inch walled steel pipe


Auger Type:

1

1/8”

cup Auger Feed System


Controls:

Country

Flame

Intelli-Choice Control Board


Electrical:

120 Volts, 2.4 Amp, 60 Hz


Measurements:

CROSSFIRE HEIGHT (at front)

22.5”

CROSSFIRE

DEPTH

(from

shroud) 14.0”

CROSSFIRE

WIDTH

(rear)

26.0”

CROSSFIRE

WIDTH

(at

shroud

mount)

25.5”


Weight :

STOVE

WEIGHT 220

POUNDS


Clearances:

UNIT

TO

SIDEWALL

7”

UNIT TO SIDE TRIM

7”

UNIT TOP TO SIDE TRIM

9.25”

UNIT TOP TO MANTLE

9.25”

HEARTH

FLOOR

TO

MANTLE

32”

NONCOMBUSTIBLE FLOOR PROTECTION (front)

6”

NONCOMBUSTIBLE FLOOR PROTECTION (sides)

6”


Shroud Measurements:

SHROUD WIDTH (standard)

42.0”

SHROUD HEIGHT (standard)

30.0”

SHROUD WIDTH (oversized)

48.0”

SHROUD HEIGHT (oversized)

32.5“