beautypg.com

American Energy Systems MagnuM T40 User Manual

Page 29

background image

29

PROBLEM

CAUSES

SOLUTIONS


? Blower will not operate.








♦ No power to stove.




♦ No power to control board.

♦ Blower is defective


9 Check to see that the stove is

plugged into the wall outlet.

9 Check to see if your circuit breaker

has “tripped”.


9 Check wire connection between the

high limit snap switch and the
terminal block.


9 Replace defective Blower


? Soot or fly ash in the house.

♦ Cleaning the window, particularly

when the stove is operating.


♦ Leakage on the joints between the

combustion fan, exhaust pipe and
“PL” vent. This will be evidenced
by dust on the impeller of the
convection fan and in the heat
exchanger tubes.

♦ Negative pressure in the home

drawing smoke and fly ash into the
home


9 Clean the glass when the unit is not

running



9 Seal any leaks in the exhaust

system with RTV high temperature
silicone sealer.




9 Have a qualified technician check

the home for negative pressure and
install proper make up air if needed.


? Buildup of soot on glass, venting and
heat exchangers

♦ Dirty fuel

♦ Negative pressure in home

♦ Air wash plugged or out of

adjustment


9 Make sure you have clean fuel
9 Pull manual draft control out

slightly to make sure that there is
app. ½ inch of fuel in firepot

9 Install outside air to unit and make

sure that the home has adequate
make-up air. (suggested 6” make-
up air into basement)

9 Clean air-wash system located on

front of firepot holder and face
plate.

CAUTION: WHEN PERFORMING ANY INTERNAL ELECTRICAL MAINTENANCE

• MOVING PARTS INSIDE OF THE CABINET MAY CAUSE INJURY. DO NOT OPERATE UNIT WITH PANELS

REMOVED OR OPEN.

• HOT PARTS. DO NOT OPERATE THE UNIT WITH PANEL OPEN.

• RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

• IN THE EVENT OF COMPONENT FAILURE, REPLACE WITH ORIGINAL FACTORY EQUIPMENT.

Replacement Parts List

Part

#

Description

Part

#

Description

Part

#

Description

RP2035

Comb./Room fan

RP2020

2 rpm 12V auger motor

RP2091

Auger assembly

RP2091

Auger Bushing kit

RPT2800

DCX-5 circuit board

RT050

Power Supply

MF3538

L-250 Hi-limit switch

MF3537

F-110 Fan switch

RT080

Pressure switch .1

RP2096

Neoprene ¼”ID hose

RT100

Standard black door

RT110

Gold Plated door

RT120

Door handle assembly

RT130

Door glass w/gasket

R0082

Glass Gasket kit

R0080

Door Gasket, ½” rope

R0080

Cover hinge gasket

RT180

Firepot

RT190

Ash receptacle buckets

RT200

Black

air

deflector

RT230

Gold air deflector

RT210

Black Cooktops (ea)

RT220

Gold Cooktops (ea)

MF3536

Door Safety switch