American Energy Systems MagnuM T40 User Manual
Page 17
17
• STANDARD VERTICAL INSTALLATION
Your Avent Wood Pellet Stove comes to you with the glass door installed in place, ready for use. The
glass is surrounded on the edges with a gasket and seated in a glass channel. It is held in place with two
(2) clips on the top and two (2) Clips on the bottom
REMOVAL OF BROKEN OR DAMAGED GLASS
Open the door and lift off of hinges. If the door is tight, tap gently on the bottom of the door with your
hand or rubber hammer. Lay door down on newspaper with glass clips facing you. Using a #2 Phillips
screwdriver, loosen the screws and take off the glass clips and bracket. Remove the broken glass
carefully and discard.
Check to make sure that the gasket material under the glass is in good shape. You can get this material
from the factory or from an authorized Avent Wood Pellet reseller if it needs to be replaced.
Reverse the above procedure for replacing new glass. When installing the new glass make sure that
the glass is binding anywhere in the glass channel. The glass will break when tightening the screws
if the glass is binding anywhere.
GLASS MAINTENANCE, ADJUSTMENT, REMOVAL AND REPLACEMENT
WARNING
DO NO OPERATE UNIT WITH BROKEN GLASS.
DO NOT SUBSTITUTE ORIGINAL FACTORY GLASS.
YOU MUST USE ONLY FACTORY AUTHORIZED GLASS:
(HIGH TEMPERATURE CERAMIC GLASS, 5MM THICK 10” X 10”)
DO NOT SLAM DOOR SHUT.
DO NOT STRIKE GLASS.
DO NOT USE ABRASIVE CLEANERS.
DO NOT CLEAN WHEN GLASS IS HOT.
The pipe lengths shown are for reference purposes only.
Your actual pipe lengths and configurations will vary
depending on installation requirements.
Adaptors to 4”, 6” and 8”
diameter approved listed
venting systems may be
used provided a minimum
of 18” of 3” diameter
Type L Pellet Vent is
used as a starter section
before making the
connection.