PROBLEM

CAUSES

SOLUTIONS


? Blower will not operate.








♦ No power to stove.




♦ Blower is defective

♦ Ductwork is inadequate and is

overheating the blower motor


9 Check to see that the stove is

plugged into the wall outlet.


9 Check to see if your circuit breaker

has “tripped”.


9 Check wire connections to make

sure that all are connected.

9 Have dealer replace blower motor
9 Correct the duct work


? Soot or fly ash in the house.

♦ Cleaning the window, particularly

when the stove is operating.



♦ Leakage on the joints between the

combustion fan, exhaust pipe and
“PL” vent. This will be evidenced
by dust on the impeller of the
convection fan and in the heat
exchanger tubes.

♦ Using a conventional vacuum

for cleaning. Ash will bypass.

♦ Negative pressure in home is

sucking the ash out of the unit
through the door when cleaning,
etc.

9 Clean the glass when the unit is not

running

9 Seal any leaks in the exhaust system

with RTV high temperature silicone
sealer.

9 Use an approved ash vacuum

system.

9 Have the home checked for negative

pressure and proper installation of
ductwork, etc.



? Buildup of soot on glass, venting and
heat exchangers


♦ Dirty fuel

♦ Wet Corn (above 15% moisture)

♦ Inadequate air supply

♦ Negative pressure in home


9 Make sure you have clean fuel
9 Dry the corn down to 11-12%

moisture if possible or mix with
wood pellets

9 Turn manual draft control open

slightly to make sure that there is
app. ½ inch of fuel in firepot

9 Install outside air to unit and make

sure that the home has adequate
make-up air. (suggested 8” make-
up air into basement)


Fuel Stirrer keeps jamming or
breaking

Buildup in the firepot
Dirty, Wet fuel
Poor fuel quality

√ Add Clean Burn additive
√ Clean and dry fuel. Try a different
fuel source.



CAUTION:
When performing any internal electrical maintenance

• Moving parts inside of the cabinet may cause injury. Do not operate unit with panels removed or open.

• HOT parts. Do not operate the unit with panel open.

• Risk of electrical shock. Disconnect power before servicing unit.

• In the event of component failure, replace with original factory equipment