beautypg.com

Troubleshooting – Desa V)CD36RN User Manual

Page 40

background image

www.desatech.com

116035-01E

40

TROUbLEShOOTING

Continued

OBSERvED PROBLEM

Burner backfiring during com-

bustion

Slight smoke or odor during initial

operation

Heater produces a whistling noise

when burner is lit

Glass soots

Fireplace produces a clicking/tick-

ing noise just after burners are lit

or shut off

Remote does not function

REMEDY

1. Clean burner (see Cleaning

and Maintenance, page 37) or

replace burner orifice

2. Replace damaged burner

3. Replace gas control

1. Problem will stop after a few

hours of operation

1. Turn gas control knob to LO

position and let warm up for a

minute

2. Operate burner until air is

removed from line. Have gas

line checked by local propane/

LP or natural gas company

3. Clean burner (see Cleaning

and Maintenance, page 37) or

replace burner orifice

1. Adjust the log set so the flame

does not excessively impinge

on it

2. Inspect the opening at the base

of the burner to see that it is

not packed with any type of

material

1. This is common. If noise is

excessive, contact qualified

service person

1. Replace 9-volt batteries in

receiver and hand-held remote

control

POSSIBLE CAUSE

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

1. Residues from manufacturing

processes and logs curing

1. Turning gas control knob to

HI position when burner is

cold

2. Air in gas line

3. Dirty or partially clogged

burner orifice

1. Flame impingement on logs

2. Debris around burner air

mixer

1. Metal expanding while heating

or contracting while cooling

1. Battery is not installed or bat-

tery is power is low