Troubleshooting – Desa V)CD36RN User Manual
Page 40

www.desatech.com
116035-01E
40
TROUbLEShOOTING
Continued
OBSERvED PROBLEM
Burner backfiring during com-
bustion
Slight smoke or odor during initial
operation
Heater produces a whistling noise
when burner is lit
Glass soots
Fireplace produces a clicking/tick-
ing noise just after burners are lit
or shut off
Remote does not function
REMEDY
1. Clean burner (see Cleaning
and Maintenance, page 37) or
replace burner orifice
2. Replace damaged burner
3. Replace gas control
1. Problem will stop after a few
hours of operation
1. Turn gas control knob to LO
position and let warm up for a
minute
2. Operate burner until air is
removed from line. Have gas
line checked by local propane/
LP or natural gas company
3. Clean burner (see Cleaning
and Maintenance, page 37) or
replace burner orifice
1. Adjust the log set so the flame
does not excessively impinge
on it
2. Inspect the opening at the base
of the burner to see that it is
not packed with any type of
material
1. This is common. If noise is
excessive, contact qualified
service person
1. Replace 9-volt batteries in
receiver and hand-held remote
control
POSSIBLE CAUSE
1. Burner orifice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
1. Residues from manufacturing
processes and logs curing
1. Turning gas control knob to
HI position when burner is
cold
2. Air in gas line
3. Dirty or partially clogged
burner orifice
1. Flame impingement on logs
2. Debris around burner air
mixer
1. Metal expanding while heating
or contracting while cooling
1. Battery is not installed or bat-
tery is power is low