beautypg.com

Fireplace installation – Desa V)CD36RN User Manual

Page 23

background image

www.desatech.com

116035-01E

3

Var

iabl

e

Fan

Sw

itch

W

hite

W

hite

Bla

ck

Gr

een

On

110

/11

5

V.A

.C.

Blo

we

r

Mo

tor

Bla

ck

Bla

ck

Bla

ck

Of

f

Figure 38 - Location of Wiring Diagram

Decal (Model May Vary From Illustration)

Wiring Diagram Decal
6" in Front of Blower

FIREPLACE

INSTALLATION

Continued

Model BKT Installation
Note:

When installing the BKT thermostati-

cally-controlled blower, you must first secure the

thermal switch bracket to the blower if it has not

already been factory installed.

1. Place the green ground wire with ring terminal

between the bottom hole on the thermal switch

bracket and the top ear hole on the blower as-

sembly. Insert the phillips screw into all three

pieces and tighten securely (see Figure 39).

Thermodisc

Figure 39 - Blower Model BKT

Air Flow
Direction

Route BKT Blower
Through This Area

Magnets

Blower
Location

Side View Firebox Bottom

Black
Wire

Phillips
Screw

Blue Wire

Ring Terminal on
Green Wire

White Wire

Thermal
Switch

Thermal
Switch
Bracket

Power Cord

Air Flow
Direction

Magnetic
Strips

2. Connect wire harness and power cord ter-

minals. Connect the blue jumper wire to the

blower motor terminal and the right side ter-

minal of the thermal switch. Connect the black

wire to the left side of the thermal switch and

the white wire to the other remaining blower

motor terminal.

Note:

The power cord outer insulation sleeve may

have to be stripped slightly to allow enough wire

length to reach and make all connections. DO NOT

trim excessive length away. Just enable enough to

make all connections securely.

3. Place the blower against the lower rear wall of the

firebox outer wrapper with the exhaust port directed

upward and the thermodisc positioned up near the

fireplace bottom. The thermodisc must be oriented

near the fireplace bottom as shown in Figure 39 in

order to sense temperature and properly operate.

The blower will be held in position against the

back wall by the magnets incorporated onto the

blower housing (see Figure 39).

4. Be certain that all wire terminals are securely at-

tached to terminals on blower motor and thermal

switch and that the screw for the thermodisc

bracket and green ground wire is tight.

5. Mount speed control box by placing plastic

control shaft through opening in switch

bracket (see Figure 36, page 22) or ignition

module bracket (see Figure 37, page 22).

6. While supporting speed control, secure control

shaft with lock nut by pushing and turning lock

nut with pliers clockwise until it is tight against

mounting plate. Place control knob provided on

shaft (see Figure 36 or 37, page 22).

7. Check to make sure that power cord is com-

pletely clear of blower wheel and that there are

no other foreign objects in blower wheel. Also

double check all wire leads and make sure

wire routing is not pinched or in a precarious

position. Correct accordingly.

8. Turn on power to duplex outlet if previously

turned off per warning in column 2, page 21.

9. Plug in blower power cord to duplex outlet.

10. The blower will only run when the speed control

knob is in the ON position and the thermal switch

senses temperature after the fireplace begins to

heat up. The blower speed can be adjusted by

rotating the control knob. To turn off, turn knob

fully counterclockwise until it clicks off. If the

blower is ON and has been running with the

fireplace operating, the blower will continue to

run for a short time after the fireplace has been

turned off. As the thermal switch cools down,

the blower shuts down automatically.